INTELLIGENT COOLING TECHNOLOGY · PRODUCT CONCEPT
NUVA OPTIMIZ COOLING / CONCEPT 01

A closer look at
how your cooling tower runs

Explore NUVA Optimiz Cooling — our development roadmap for monitoring, energy analytics and AI-assisted control of industrial cooling towers. Interact with the simulation, estimate thermal duty, and send us your operating requirements.

IN DEVELOPMENT · SIMULATION

01 MONITOR02 ANALYZE03 OPTIMIZE
●   SIMULATED DATA · NOT CONNECTED TO EQUIPMENT+
WATERFANFILL
Fan speed78%
Cold water32.0°C
Estimated fan input7.1 kW
THERMAL ENGINEERING
✳
INDUSTRIAL MONITORING
✳
ENERGY OPTIMIZATION

01 / INTERACTIVE SYSTEM DEMO

Try changing the fan speed

Move the fan-speed slider to simulate the effect on a tower fan. The illustration and plotted values are indicative, not measured, and do not represent a validated tower performance model.

◉  DEMO / SIMULATED
Cooling tower digital twinSIMULATION

Concept animation, not a live factory connection

✳≋ ≋ ≋
Hot water (°C)37.0 °C
Cold water32.0 °C
Wet-bulb (°C)27.0 °C
Est. motor kW7.1 kW
78%
40%70%100%

02 / ENGINEERING TOOLS

Cooling Tower Calculator

Enter the flow rate and water temperatures to estimate heat rejection. If you’d like us to review the figures, include them in your enquiry.

OPERATING CONDITIONS ⌁

Assumes clean water (ρ≈1,000 kg/m³, cp≈4.186 kJ/kg·K). Formula Q≈1.163 × m³/h × ΔT. RT is thermal equivalence, not a manufacturer-rated cooling tower selection. Actual tower selection requires site wet-bulb conditions and vendor performance data.

PRELIMINARY CALCULATION THERMAL ONLY

Sample data

Heat rejection581.5 kW
Thermal equivalent165.3 RT
Cooling range5.0 °C
Cooling approach5.0 °C
Use these values in my inquiry ↗

03 / ENERGY ASSESSMENT

Estimate potential fan energy savings

Explore a theoretical VFD fan-power scenario based on the affinity-law approximation. It is not a guarantee of savings or an AI prediction.

Assumes 100% baseline speed, equal annual run hours and P ∝ RPM³. Actual fan-system curve, VFD efficiency, minimum airflow, water temperatures and chiller consumption can change results. Do not reduce fan speed without checking site conditions.

Sample data

Fan input only · idealized affinity law

Theoretical annual fan-only saving

197,640 THB
Baseline kWh/y90,000
Illustrative kWh/y46,080

04 / PRODUCT DEVELOPMENT

What we plan to build next

Capture measurements → understand performance → recommend safe setpoints → validate savings.

01

01 / Monitoring

Sensors, historian, operating trends and alarms. First prototype target.

PLANNED PROTOTYPE
02

02 / AI Advisor

Validated diagnostics and optimization recommendations, reviewed by operators.

FUTURE ROADMAP
03

03 / AI Control

Future PLC/VFD integration with permissions, local interlocks and manual override.

FUTURE ROADMAP

ⓘ Product is under development. No real-time integration, savings guarantee or autonomous controls are provided in this website demo.

05 / PROJECT INQUIRY

Let’s assess your cooling system.

Send the calculated duty and your project details to NUVA. The current static-site version prepares an email using your own mail app; it does not upload information to a company database.

REQUEST FOR ENGINEERING ASSESSMENT EMAIL RFQ
Flow 100 m³/h · 37 / 32 / 27 °C · 581.5 kW

Email opens on your device for review and sending. No request is submitted automatically. For drawings or photos, attach them in your email or send via LINE.

Information entered here stays in your browser until you open email or copy it.

ⓘ   Engineering note: final tower selection and any VFD/PLC control changes require verified OEM data and a site safety review.