Maintenance & Repair

We check the equipment, help identify what needs attention and plan maintenance around the time you can take the system offline.

Request a Quotation
Cooling tower belt and pulley drive
From the team’s field experience

What the work can include

Preventive Maintenance

Agree inspection points, maintenance tasks and reporting for scheduled work.

Fan & Motor Maintenance

Inspect accessible blades, hubs, motor mounts and fasteners.

Gearbox Inspection

Review visible leaks, mounting and operating symptoms.

Belt & Pulley Alignment

Inspect the drive and set alignment and belt tension to the applicable equipment requirements.

Mechanical Repair

Identify worn or damaged components and agree repair or replacement options.

Cooling Tower Leak Repair

Trace accessible leaks and review basin, seams and connection points before repair.

Equipment Inspection

Record condition, observations and recommended follow-up actions.

What to know before starting

GENERAL INSPECTION

Understand equipment condition.
Plan maintenance and improvements.

General cooling tower inspections assess accessible equipment for wear, damage, leakage and operating concerns. Deliverables can include an observation list, site photos and recommendations within the agreed scope.

Fans & drive systems

Review blades, fastenings, gearboxes, shafts, belts and pulleys as applicable.

Internals & structure

Inspect accessible fill, nozzles, drift eliminators, basins, structure and supports.

Operating information

Review symptoms and maintenance history. Additional checks, such as current or vibration measurements, are included when agreed in the scope.

Discuss your project on LINE ↗

STRUCTURAL REPAIR & REPLACEMENT

Cooling tower structural repair and replacement

NUVA undertakes surveys, repair planning, component replacement and installation for cooling tower structures, coordinated with mechanical and piping work.

Corrosion visible at existing beam and column connections
Existing condition · beam, column and connection inspection
Existing internal frames, bracing and cooling tower fill
Existing condition · internal frames and fill supports

Columns, beams and bracing

Inspect material loss, connections and foundations. Define local repair or member replacement from the assessment.

Fill supports, decking and walkways

Review supports and maintenance access; compare suitable steel or FRP products under an engineering design.

Surface protection and site execution

Specify surface preparation and protective coating for suitable repairable members. Plan temporary supports, dismantling and installation around shutdown constraints.

These are existing-condition photos, not completed structural repair examples. Repair scope and material selection require inspection and an engineering assessment. Coating does not restore lost structural section.

Request a structural site survey ↗